Get a quote
Free calculator

Septic tank distance checker: how far from the house, borehole or well?

Enter how far your septic tank and soakaway are from the house, boundary, borehole or well, river and pool, and see which distances are fine and which to check with the council.

A soakaway trench being set out at a safe distance from a borehole on a South African plot
Soakaway, house
3 m or more, also from boundary
Borehole or well
30 m minimum, often 50 m+
Sand or dolomite
Up to 100 m from a borehole
River or dam
30 m or more, above flood line
Final say
Your municipality

Your distances

Measure in metres from the tank and from the soakaway. Leave a line blank if it doesn't apply.

Used for drinking water.
Shallowest level in the wet season.

Result

–

Lines checked
–
OK
–
Check with council
–
Too close
–

    Septic tank distance from a borehole is the question we hear most, followed by how far a septic tank should be from the house and the septic tank to well distance. The short answer: keep the soakaway at least 3 m from buildings and boundaries, and keep the tank and soakaway at least 30 m from any borehole, well or spring used for drinking, with 50 m or more on many plots and up to 100 m on sandy, fractured or dolomitic ground. The figures below are common South African guidance, and your municipality sets the real distance for your stand.

    How far should a septic tank be from the house?

    A septic tank is normally kept at least 3 m from buildings so that the excavation does not undermine foundations and so a honey sucker can reach the lid. The soakaway matters more: the City of Cape Town conditions put it at least 3 m from any building or boundary, and other councils usually ask for something similar. Never build, pave or park over the tank or soakaway, and keep the soakaway out of vehicle routes. The soakaway also needs a plot of reasonable size; Cape Town generally wants at least 900 m² for a tank and soakaway.

    If your house is closer than 3 m, a shorter, deeper soakaway pit, a French drain placed on another side of the property or a sealed conservancy tank may be the answer.

    Septic tank distance from a borehole, well or spring

    Effluent carries bacteria and nitrates that travel through soil and rock, so the septic tank to well distance is the one that protects your family's health. Most guidance puts the minimum at 30 m for a borehole, well or spring used for drinking, and many councils and designers ask for 50 m or more. On sand, fractured rock or dolomite, where the effluent moves quickly and far, up to 100 m is asked. Where the ground slopes, put the soakaway downhill of the borehole, not above it.

    If you can't reach those distances, don't just squeeze in closer: ask the council or an engineer about a lined system, a sewage treatment plant or a sealed tank. Also keep clear of rivers, vleis and dams: 30 m or more is the planning figure, and stay above the flood line.

    Septic tank distance reference table

    Common minimum distances, in metres
    FromTankSoakawayNotes
    House or building33Cape Town condition for soakaways. Never build over either.
    Boundary1 to 33Cape Town: 3 m for the soakaway.
    Borehole, well or spring30 to 50+30 to 50+Up to 100 on sand, fractured rock or dolomite.
    River, dam or vlei30+30+Planning figure. Stay above the flood line.
    Swimming pool3 to 53 to 5No fixed national figure.
    Driveway1+3+Traffic-rated lid if the tank is under a drive.
    Water tablen/a1 m clearTrench base at least 1 m above the highest seasonal level.

    Planning guides drawn from City of Cape Town conditions and common practice. Any one council can ask for more. Plot size: Cape Town generally wants at least 900 m².

    What to do if a distance is too close

    A flag means "talk to the council", not "can't be built". The building control officer can accept a smaller distance with a design, or ask for a bigger one on porous ground. Get a septic design from a registered person, run the soakaway size calculator so you know the trench length you need, and check the tank size too. A pump-out truck also needs to reach within about 30 m of the lid, so keep that in mind when you choose the position.

    Frequently asked questions

    How far should a septic tank be from the house?
    A septic tank is usually kept at least 3 m from the house. The soakaway must be at least 3 m from buildings and boundaries under City of Cape Town conditions, and other councils ask for something similar. Never build over the tank or soakaway.
    What is the septic tank distance from a borehole?
    Commonly 30 m is the minimum between a septic tank or soakaway and a borehole used for drinking, and many councils ask for 50 m or more. On sandy ground, fractured rock or dolomite it can be up to 100 m. The council sets the real figure for your area.
    What is the septic tank to well distance?
    The same as for a borehole: at least 30 m in most guidance, often 50 m or more, and further on porous ground. Hand-dug wells and springs are shallower and more easily contaminated, so don't try to get by with the minimum.
    How far should a soakaway be from the boundary and a river?
    At least 3 m from the boundary under City of Cape Town conditions. From a river, dam or vlei, use 30 m or more as a planning figure, and stay above the flood line. Your municipality has the final say.

    More calculators and tools

    Get a free septic quote

    Fill in the job card: your tank or what you need, how many people use it, when it was last pumped and how close a truck can park. Operators, contractors and suppliers who work in your area quote you directly. Free, no obligation.

    Pump-out job cardJob no. assigned when sent

    Tanks and items

    No.Tank or itemQtyUnitRemove
    T1
    T2
    Up to 10 lines. Not sure of the size? Leave it empty.

    Add the tank size in litres to see roughly how many tanker loads it is and how often it needs pumping.

    Symptoms and options

    Free and no obligation. By sending you agree that we may share your request with a suitable operator, contractor or supplier. See our privacy policy.

    Get a free quote