A conservancy tank is a sealed tank with no outlet, so everything that goes in stays there until a honey sucker takes it away. That makes the size of the tank and the number of people using it the whole story: a small tank with a full house can need emptying every week. This calculator shows how many days a tank lasts, what that costs each month, and what size to install if you are choosing one.
How fast a conservancy tank fills
The daily flow is the number of people multiplied by the litres each uses. A planning figure for wastewater going into a sealed tank is 100 litres per person per day, with a range of about 80 to 150. Low-flow taps and showerheads, and sending greywater to a garden, bring the figure down.
Days until full = tank litres ÷ (people × litres per person per day + extra flow)
e.g. a 5,400 L tank, 4 people: 5,400 ÷ 400 = 13.5 days
Emptyings per year are 365 divided by the days until full. Each emptying uses one tanker load if the tank is up to 10,000 litres, which is the usual planning size for a honey sucker. Tankers range from about 5 kL to 16 kL, so a larger tank may take two loads or one trip with a big truck.
Days until full by tank size and household
| Tank size | 2 people | 4 people | 6 people | 8 people | 10 people |
|---|---|---|---|---|---|
| 5,400 L | 27 | 14 | 9 | 6.8 | 5.4 |
| 10,800 L | 54 | 27 | 18 | 14 | 11 |
| 16,200 L | 81 | 41 | 27 | 20 | 16 |
| 21,600 L | 108 | 54 | 36 | 27 | 22 |
| 27,000 L | 135 | 68 | 45 | 34 | 27 |
Call the operator a few days before the tank is full, not on the day. Overflow is a health hazard and an offence in most municipalities.
Sizing a new conservancy tank
The conditions used by councils such as the City of Cape Town set a minimum of 5,400 litres or two days of flow, whichever is more, in multiples of 5,400 litres. Beyond that minimum, the size is a trade-off between the cost of a bigger tank and the cost of more emptyings.
Tank (L) = daily flow × days between emptyings, at least 2 days and at least 5,400 L, rounded up to a multiple of 5,400
e.g. 4 people, 400 L a day, 20 days: 8,000 L, so 10,800 L
A tank that lasts three or four weeks suits most homes. A busy lodge or a staff compound will need more storage, or a more frequent tanker, or a different system. Compare the cost of emptyings with a septic tank and soakaway, or with a package sewage treatment plant, before you decide. A tank with a full-level alarm saves the guesswork.
What emptying costs
A sealed home tank usually costs R650 to R2,200 per emptying, and municipal tariffs can be lower. Long hose runs over 30 metres, a buried lid, after-hours calls and travel beyond about 30 km cost extra. Because the tank fills quickly, even a modest price adds up: two emptyings a month at R1,400 is R2,800. See conservancy tank emptying and conservancy tanks for more, or estimate a single visit with the cleaning cost calculator. These figures are planning guides: the operator's quote and your municipality's rules have the final word.